10.2 Display and Operation Panel of SDP


The SDP drive equips a 5-digit, 7-segment LED display and 4 pushbuttons. The operation are described below.


Name

Function Description

Monitor

5-digit, 7-segment LED to show motor status, parameters, and abnormal messages.

MODE key

Display mode change. Shift digit when it is in parameter editing mode.

UP key

To scroll up the display or increase the data.

DOWN key

To scroll down the display or decrease the data.

SET key

To show or save the value which is operated.


Press MODE key once to shift to the next display mode. Press the UP or DOWN key to scroll the display data in this mode. When it reach the desired data, press SET key to show the value of this data.


Take setting the value of PD01 as an example. User has to operate the following step after SDP boot up.


1.

Press MODE key until PD01 is shown on the monitor.

2.

Press UP or DOWN key to scroll the data in PD mode. Scroll it to PD01.

3.

Press SET key and the value of PD01 would show on the monitor.

4.

Press SET key again. Press UP or DOWN key to modify the value after the digit starts flashing.

5.

Press MODE key to shift the digit of editing and press UP or DOWN key to modify it.

6.

Press SET key to save and leave after the setting is done.