12.1 Fatal System Alarms


Code

Warning Message

Solution

514

X position control loop fail

Close for 10 seconds and re-open, if problem continue, please check X, Y, Z, A, B, C axis servo driver, motor and connection to be correct or not.

515

Y axis servo position loop not normal

Same as 514.

516

Z axis servo position loop not normal

Same as 514.

518

PLC Alarm (EMG input is on)

Emergency stop

According to PLC dealing with emergency machine stop, it could be due to e.g. EMG button is pressed, motor or servo motor driver is broken.

519

X axis not in-position time out

X, Y, Z, A, B, C axis servo system cannot follow, many reason can cause it. Resolution same as above.

520

Y axis not in-position time out

Same as 519.

521

Z axis not in-position time out

Same as 519.

546

Rigid tapping spindle motor close loop not working normal

Check the motor driver, is the motor and cable properly connected.

577

Emergency stop is pressed

The emergency stop switch is pressed. Rotating to release it after trouble clearing.

579

Spindle Alarm

Please check the status of the spindle driver.

580

HandCrank/Servo switching fail

Abnormal servo enable/disable when toggling the handcrank mode. Please check the status of the servo driver and reboot.

581

axis ABS reset fail

Please check the status of the servo driver and execute this action after reboot.

582

Spindle input time out

Please check if "speed arrived" and "zero speed" signals from inverter are functional.

583

Spindle Gear Error

Please confirm that spindle shift to the proper gear according to current spindle speed.

584

Axis servo drive alarm

Please check if axial drive is in alarm atatus.