12.1 Fatal System Alarms
Code |
Warning Message |
Solution |
514 |
X position control loop fail |
Close for 10 seconds and re-open, if problem continue, please check X, Y, Z, A, B, C axis servo driver, motor and connection to be correct or not. |
515 |
Y axis servo position loop not normal |
Same as 514. |
516 |
Z axis servo position loop not normal |
Same as 514. |
518 |
PLC Alarm (EMG input is on) Emergency stop |
According to PLC dealing with emergency machine stop, it could be due to e.g. EMG button is pressed, motor or servo motor driver is broken. |
519 |
X axis not in-position time out |
X, Y, Z, A, B, C axis servo system cannot follow, many reason can cause it. Resolution same as above. |
520 |
Y axis not in-position time out |
Same as 519. |
521 |
Z axis not in-position time out |
Same as 519. |
546 |
Rigid tapping spindle motor close loop not working normal |
Check the motor driver, is the motor and cable properly connected. |
577 |
Emergency stop is pressed |
The emergency stop switch is pressed. Rotating to release it after trouble clearing. |
579 |
Spindle Alarm |
Please check the status of the spindle driver. |
580 |
HandCrank/Servo switching fail |
Abnormal servo enable/disable when toggling the handcrank mode. Please check the status of the servo driver and reboot. |
581 |
axis ABS reset fail |
Please check the status of the servo driver and execute this action after reboot. |
582 |
Spindle input time out |
Please check if "speed arrived" and "zero speed" signals from inverter are functional. |
583 |
Spindle Gear Error |
Please confirm that spindle shift to the proper gear according to current spindle speed. |
584 |
Axis servo drive alarm |